Laboratory Vertical Steam Sterilizers. (with cooling option) models. , , ELV and. , , ELVC. Cat. No. MANE Rev A. Heidolph Tuttnauer Vertical Top-Loading Autoclave Model ELV, Mobile; V 50/60Hz Healthcare:General Laboratory Equipment:Autoclaves, Sterilizers, . Tuttnauer ELV Vertical Autoclave series- 85L. It a top loading model with advanced multi-color control panel and a chamber made of L or Ti.

Author: Zulum Mezinris
Country: Mexico
Language: English (Spanish)
Genre: Marketing
Published (Last): 21 September 2018
Pages: 433
PDF File Size: 3.49 Mb
ePub File Size: 12.79 Mb
ISBN: 734-3-28265-554-8
Downloads: 35826
Price: Free* [*Free Regsitration Required]
Uploader: Zulkikree

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

The right system for every type of sterilization.

Additional options ensure even more efficient work, with control of results and optimal, safe and reproducible sterilization processes. Via state-of-the-art microprocessor technology. For pressure, temperature, time and errors.

Preselected parameters remain programmed until altered. A PT temperature sensor in a reference vessel guarantees that the set sterilization temperature is actually attained before sterilization starts.

  BYZNYS V PLN NAHOT PDF

Demineralised water level 38770. Feed water for steam generation is automatically regulated. Exhaust steam is cooled down before leaving the autoclave. No unnecessary steam is exhausted. Drainage equipment protected from contact with steam. Heat-resistant plastic covering on lid. Prevents contact with ekv parts and protects from burning. Prevents the door from being opened whilst under pressure. In conjunction with temperature measurement in a reference vessel, the system prevents the door from being opened until the temperature is below a specified level.

Systec ELV used with warranty. Used Systec ELV from

Hence preventing delayed boiling as specified by technical regulations for pressure vessels, complies with British-and German Standards. Door lock safety switch. Prevents the sterilization programme from being started if the door is not properly closed.

Water level safety device. Prevents the autoclave from being heated up if insufficient water is available for steam generation. Excess temperature safety device.

Switches off the heating elements if too high a temperature is attained. Release of too high pressure. Short batch times with intelligent technology.

  BERGMANN 3012 PDF

The actual sterilization time of e. Especially when sterilizing liquids, the heating and cooling phases are much longer. In addition, this also means that media need not be exposed unduly long to high temperatures. In conventional autoclaves, the prescribed temperature may well be reached in the vessel, but the rlv to be sterilized may only be at e.

VERTICAL AUTOCLAVE-ELV SERIES- 85L

This system is different! Due to the dual temperature and pressure control, the chamber pressure and hence temperature is increased in the heating phase. Temperature equilibrium is thus attained much more quickly and the overall sterilization time is shorter. This system can also be fitted retrospectively.

On January 1st

Technical data serie ELV. Chamber volume in litres. External dimensions W x H x D. Heating performance in KW.